         Model RS Chimney Fan
 Eliminates smoke & odors
 | Exhausto 
	is nowENERVEX
 RS Chimney Fans
 
 
     | 
     
    World's Finest Mechanical Draft Systems.
 
    The guaranteed solution to 
	smoking or poor drafting wood and gas fireplaces.
 Venting for wood and coal 
	stoves, residential
 pizza ovens, bbq's and grills.
 |  
    
    
		
			| If you were never able to use your wood burning 
			fireplace or wood 
    stove for fear of smoke, you can now. Also exhausts coal, oil and gas fumes.
 |  |  |  
    
    
    On a mission to make that fireplace or wood 
    stove work? We will go over every 
    possible solution before we recommend an RS chimney fan.  In some cases the fan 
    is just the most economical choice.  Can you imagine going through the 
    expense of lining, insulating or extending the chimney and finding the same 
    problems.  Or the many different types of  “downdraft” caps and adaptors with 
    no success.
 Chimney caps,
    vacustacks and turbines all have their selected “specific” application as a 
	possible downdraft cap to help solve a draft or smoke problem.  It is 
	when you need the benefits of all at once that you know there is a 
	guaranteed solution by using the Enervex RS 
    Chimney Fans.
 
		
			| Easy No-Mess Installation Quiet operation
 Eliminates smoke odors
 Easy to operate
 Low operating cost
 Variable speed motor
 |  |  |  | You will find ENERVEX RS Chimney Fans on chimneys on The 
	White House in D.C., The Statue of Liberty in New York, in Disney 
	World in Florida and in California, and in many hotel and restaurant 
	chains throughout the US. |  
			| 6 month 
			unconditional 
	money back guaranty, 2 yr factory warranty & 10 yr corrosion perforation 
	warranty CLICK TO VIEW 
			 
			Chimney Fan Warranty
 If you are not completely satisfied with the RS 
	chimney fan, it can be returned for a full refund, less shipping, for up to 
	6 months after the date of purchase.
 This does not include accessories such as 
	adapters or controls.
 |  |  Go to
	: 
    
    Chimney Fan Sizes Go to : 
    
    Chimney Fan Warranty
 
 Chimney Caps & Downdraft Solutions
 Go to : Chimney Cap Selection
 Go to : 
      Downdraft &
      Wind Loading Explanations.
 |  
			|  |  | Pricing & Ordering info |  |  |  
 
  
    
    
      
        | 
          | Click here to visit theChimney 
Fan Source 
@ 
		 
		
		chimneyfansource.com
 to learn more about Enervex RS chimney 
		fans
 and the accessories that may go with an installation
 
			
				|  |  |  |  |  
				| Flue Pipe Adaptors | Wireless Speed 
				Control | ADC 100 for Gas Fireplaces | MFD 
				Mechanical Fireplace Damper |  
        
        Mechanical draft fan for installation at the chimney termination point, 
        vertically or for side-wall venting. Assures a negative pressure in the 
        entire chimney or stack system. 
         A 
        residential type chimney top mounted fan to be used in conjunction with 
        wood, gas, oil and coal fired appliances. The fan can be used with 
        fireplaces, fireplace inserts, stoves, ovens, BBQ's, water heaters, 
        furnaces, small boilers and more.   The Exhausto RS chimney fan mounts 
        outside, atop the chimney, where it literally sucks the smoke from the 
        flue. It can be installed on any type chimney system, whether it is made 
        of steel, masonry or cast material (installation on pre-fabricated 
        chimneys requires a special adapter). The variable 
        speed motor assures the chimney fan will never "over-draft" the heating 
        appliance. The speed can be adjusted to provide a perfect draft. 
         
        The Exhausto fan housing is hinged and the top can be opened for easy service 
        and access to stack. For use with gas, wood or solid fuel. 
        The RS chimney fan is designed for 
        minimum energy consumption, using about as much energy as a regular 
        light bulb. Standard equipment include: 
        fan, mounting brackets, gasket, 5 Amp fan speed control and a pre-wired 
        weather tight junction box.  The fan also duplicates as a ventilator: Simply turn it off to rid 
		your home of stale air, cigarette smoke, etc.
 |  
        | Features: Enervex RS Chimney Fan
 
          Used with oil, gas, wood and 
          coal. Energy efficient motor is 
          standard. Cast aluminum construction.
          Low silhouette and low 
          weight. 
          Quiet operation.
           Variable speed. Fan opens for easy cleaning.
          Easy to install. 2 Year Factory Warranty.
          10 Year Corrosion 
          Perforation Warranty. 6 Months Performance 
          Guarantee. ETL-listed to UL 378 
          Standard for Draft Equipment.  The Enervex RS fan is a guaranteed solution?  It 
        works on…  
          Wood / Coal StovesFireplace InsertsPellet / Corn StovesGas / Propane FireplacesBasement Stoves & Fireplaces2 - 3 Sided & Open Pit 
          Fireplacesundersized fluescold outside wall chimneyschimney linersshort chimneyshigh wind areas |  
 Learn more about Enervex Chimney FansPlease take a moment to view our most 
frequently asked questions about our fans.
 What happens when you have a 
fire in the fireplace and a power failure occurs?You will most likely experience the same 
problems you had before the chimney fan was installed.
 What if the chimney has a 
constant down-draft and odor when not in use?Run the chimney fan at a low speed.
 Does the fan always have to be 
on when I have a fire in the fireplace?Yes, the motor can only be cooled when the 
chimney fan is operating. You may, however, run it at a very low speed.
 The fireplace spills due to 
negative pressure in the house. Won’t the chimney fan add to the problem?Any exhaust fan will pull air out. However, 
proper use of the fan speed control assures the chimney fan simply simulates the 
natural draft required for the fireplace to operate. Thus, the chimney fan will 
not exhaust more air than a well-functioning fireplace would have done.
 *It is important to 
emphasize that all furnaces, water heaters and other combustion equipment be 
checked for proper venting before regular use of a chimney fan.
 Can the fan be recessed or 
hidden?Yes, the fan may be recessed or hidden, for 
example, with chimney pots, copper caps, or cupolas* 
as long as the fan is allowed to vent properly.
 Does the chimney fan have to 
be removed every time I have my chimney cleaned?No, the fan has hinges on which it can be 
tilted open for easy access of the chimney.
 Does the fan require its own 
circuit?No, the fan only draws about 1 to 4 amps, 
depending on the size, and runs on 110 volts, which is standard in most homes.
 Can you run the wire inside 
the flue?No. However, you may run it inside a chase. 
Otherwise it will have to be run on the outside of the chimney.
 What kind of guarantee do I 
have that I will be satisfied with the fan?Enervex offers a 6-month unconditional 
guarantee, 2-yr factory warranty on motor and a 10-yr corrosion perforation 
warranty.
 
 We have combined Enervex's superb technical 
support with our own expert service 
and knowledge of this product to make us your Chimney Fan source. 
Enervex 
Fans are guaranteed to work...Let us help size and price your chimney 
fan. Do you need a Chimney Fan?  
We can tell you why. Call  1-800-685-8263 or e-mail us at
volkosupply@yahoo.com 
 
	
		|  |  |  |  
		| If you need to mechanically exhaust smoke or fumes we have the 
draft fan. 
Help draft wood burning fireplaces & woodstoves, 
gas log fireplaces, pellet stoves, kitchen hoods, indoor & outdoor bar-b-que 
grills, chimineas, pizza ovens and just about any other appliance that exhausts 
using a chimney or smoke pipe.  Definition of Mechanical Venting While used for decades in Europe, mechanical venting of 
fireplaces and stoves is relatively new in USA. Building codes, ANSI and NFPA 
standards hardly mention "mechanical venting". And, when mechanical venting is 
mentioned it is referred to as "draft inducing", which leads to "draft inducing 
equipment".  "Draft inducer" has become trade name for a paddlewheel fan that 
is inserted into the flue between the appliance outlet and the chimney 
termination. There is still a misconception about mechanical venting. Many 
professionals still don't understand the difference between draft inducers and 
chimney fans. These are our definitions that should explain the major 
differences: Draft Inducer: "A fan or ventilator that is installed 
between the appliance outlet and the chimney termination. The draft inducer 
creates a negative pressure on the inlet side and a positive pressure on the 
outlet side." Chimney Fan: "A fan or ventilator that is installed at the 
chimney termination. The chimney fan creates a negative pressure in the entire 
chimney system". Obviously, by pressurizing the flue the draft inducer can not 
be used in any stack or chimney flue that is exposed to living quarters. Using 
an in-line draft inducer almost always creates problems with warranties provided 
by stack and chimney manufacturers, and if the chimney system is listed the 
installation of a draft inducer will definitely void the listing. Further, the 
draft inducer is neither made nor designed for use in a dirty environment with 
creosote. On the other hand, a chimney fan can be used on any type stack 
or chimney flue because it does not pressurize anything. |  | Got a wood stove 
		with a smoke problem? 
 |  
		|  |  |  |  
 Draft Inducers for oil 
		or gas furnaces and water heaters. 
     |